Institutional accounts · Research use only
  • ISO 9001 Certified
  • Manufacturer Direct
  • Worldwide Shipping
VeyaPeptide
50+可选标记种类
FRET供体-受体对
HPLC纯化并质谱验证
N / C / 侧链标记位点

Veya Peptide synthesizes fluorescently and functionally labeled peptides for imaging, binding, and detection assays. We conjugate a wide range of fluorophores, biotin, and chromophores at the N-terminus, C-terminus, or a specific side chain, then HPLC-purify and mass-verify every conjugate.

Label position matters: an incorrectly placed dye can disrupt binding or quench signal. Our chemists advise on the optimal attachment point and linker for your assay, whether you need a single reporter or a matched FRET donor–acceptor pair.

Fluorescent Labels

We offer the full range of common research fluorophores across the visible and near-IR spectrum:

  • Fluorescein family — FITC, 5/6-FAM, and carboxyfluorescein.
  • Rhodamine / red dyes — TAMRA, TMR, Rhodamine, and Texas Red.
  • Cyanine & near-IR — Cy3, Cy5, Cy5.5, and Cy7 equivalents for deep-tissue imaging.
  • Coumarins — AMC/MCA and EDANS for enzyme-substrate work.

Affinity Tags & FRET Pairs

Beyond single fluorophores, we build peptides for pull-down, immobilization, and ratiometric sensing.

  • Biotin — with or without an aminohexanoic-acid (Ahx) spacer for streptavidin capture.
  • FRET / quencher pairs — EDANS/DABCYL, FAM/TAMRA, and Mca/Dnp for protease and conformational assays.
  • Click handles — azide/alkyne functionalization for bio-orthogonal conjugation.

Service Specifications

Parameter Specification
Label classes Fluorophores · biotin · chromophores · quenchers
Attachment site N-terminus · C-terminus · specific side chain
Spacers Ahx / mini-PEG linkers available
FRET pairs EDANS/DABCYL · FAM/TAMRA · Mca/Dnp
Purity >95% (up to >99% on request)
QC RP-HPLC + MS; UV/Vis label confirmation
Turnaround 2 – 4 weeks typical

Frequently Asked Questions

Where should the label go?

It depends on your assay. To preserve a binding motif we place the label away from it (often the opposite terminus) with a short spacer. We advise per project.

Can you make an internally-quenched FRET substrate?

Yes. We routinely synthesize protease substrates with a donor fluorophore and internal quencher (e.g., Mca/Dnp) for continuous kinetic readouts.

Do labeled peptides need special handling?

Store lyophilized, protected from light, at −20 °C. We provide handling and reconstitution guidance with each conjugate.

Order Labeled Peptides

Send your sequence, desired label(s), and assay context, and we will recommend the attachment chemistry and confirm a quote. Contact our team to start.

WhatsApp Email